Have any questions?
CONTACT US
 HDR-60 Ultra Slim Step Shape DIN Rail Power supply
 HDR-60 Ultra Slim Step Shape DIN Rail Power supply
 HDR-60 Ultra Slim Step Shape DIN Rail Power supply
 HDR-60 Ultra Slim Step Shape DIN Rail Power supply
 HDR-60 Ultra Slim Step Shape DIN Rail Power supply
 HDR-60 Ultra Slim Step Shape DIN Rail Power supply

HDR-60 Ultra Slim Step Shape DIN Rail Power supply

Advantage

> Clean production environment

> Full automatic testing with various tests

> Standardized production process with trained workers

> Low failure ratio and 24-month warranty

> Strong R&D and engineering support

Request a Quote  
 HDR-60 Ultra Slim Step Shape DIN Rail Power supply
 HDR-60 Ultra Slim Step Shape DIN Rail Power supply
 HDR-60 Ultra Slim Step Shape DIN Rail Power supply
 HDR-60 Ultra Slim Step Shape DIN Rail Power supply
 HDR-60 Ultra Slim Step Shape DIN Rail Power supply
 HDR-60 Ultra Slim Step Shape DIN Rail Power supply

Model

HDR-60-5

HDR-60-12

HDR-60-15

HDR-60-24

HDR-60-48

DC Voltage

5V

12V

15V

24V

48V

Rated Current

6.5A

4.5A

4A

2.5A

1.25A

Current Range

0 ~ 6.5A

0 ~ 4.5A

0 ~ 4A

0 ~ 2.5A

0 ~ 1.25A

Rated Power

32.5W

54W

60W

60W

60W

Ripple & Noise (max.)

80mVp-p

120mVp-p

120mVp-p

150mVp-p

240mVp-p

Voltage Adj. Range

5.0 ~ 5.5V

10.8 ~ 13.8V

13.5 ~ 18V

21.6 ~ 29V

43.2 ~ 55.2V

Voltage Tolerance

±2.0%

±1.0%

±1.0%

±1.0%

±1.0%

Line Regulation

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

Load Regulation

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

Setup, Rise Time

500ms, 50ms/230VAC 500ms, 50ms/115VAC at full load

Hold Up Time

30ms/230VAC 12ms/115VAC at full load

Voltage Range

85 ~ 264VAC (277VAC operational ) 120 ~ 370VDC (390VDC operational )

Frequency Range

47 ~ 63Hz

Efficiency

85%

88%

89%

90%

91%

AC Current

1.2A/115VAC 0.8A/230VAC

Inrush Current

COLD START 30A/115VAC 60A/230VAC

Over Load

105 ~ 160% rated output power

Hiccup mode when output voltage <50%, recovers automatically after fault condition is removed

Constant current limiting within 50% ~100% rated output voltage, recovers automatically after fault condition is removed

Over Voltage

5.75 ~ 6.75V

14.2 ~ 16.2V

18.8 ~ 22.5V

30 ~ 36V

56.5 ~ 64.8V

Protection type : Shut down o/p voltage, re-power on to recover

Working Temp.

-30 ~ +70℃ (Refer to "Derating Curve")

Working Humidity

20 ~ 90% RH non-condensing

Storage Temp., Humidity

-40 ~ +85℃, 10 ~ 95% RH non-condensing

Temp. Coefficient

±0.03%/℃ (0 ~ 50℃) RH non-condensing

Vibration

10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6

Operating Altitude

2000 meters

Withstand Voltage

I/P-O/P:4KVAC

Isolation Resistance

I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH

MTBF

927.6K hrs min. MIL-HDBK-217F (25℃)

Dimension

53*90*54.5mm (L*W*H)

Packing

190g;60pcs/12.4Kg/0.97CUFT

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”

5. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Message Feedback
If you have any enquiry about quotation or cooperation,please free to email us at Winston or use the following enquiry form,Our sales representative will contact you within 24 hous.thank you for your interest in our products.
News Center
What Is a Switching Power Supply?
Most electronic devices need specific, steady power to work properly. But the electricity from outlets or batteries often isn't in the right form for these devices. That's where a switching power supply plays a key role. This guide explains exactly what it is, how it works, and why it matters for your devices.
2025-09-06
Can a Motor Soft Starter Adapt to Different Motor Scenarios and Simplify Maintenance?
Motors have hidden risks—like repeated small mechanical shocks that shorten their life, or electrical mismatches that fail compliance checks. Old solutions only fix obvious problems, but a Motor Soft Starter is made to tackle these less-noticed issues.
2025-08-29
Why Motor Soft Starter Is a Must-Have for Modern Motor Control?
Motors power almost every industrial and municipal task—from water pumps to factory conveyors. But their start-up process hides big problems: sudden electrical surges that mess with power grids, and harsh mechanical jolts that break equipment. Old-fashioned starting methods only make these issues worse, leading to frequent breakdowns and costly fixes. A Motor Soft Starter is the simple solution to these headaches.
2025-08-25
The Key Role of Frequency Converter in Electrical
In the vast and ever - evolving field of electrical engineering, the frequency converter has emerged as a transformative and indispensable device. It has revolutionized the way electrical systems oper
2025-06-24

GET A QUOTE

AFFORDABLE PRICE: AS A MANUFACTURER, WE GIVE YOU FACTORY PRICE
Contact Us For Free Sample
×